MR62E Controller Setup

MR62E Controller Setup

1.0 Introduction

MR62E controller

 

The following steps explain how to add an MR62E controller to Borealis. The most important thing to be aware of is the fact that you must first add an LP4502 controller to Borealis before you can add the MR62E.

 

 

2.0 Add an LP4502 and Verify it is Online

  1. From the Borealis main menu, go to Hardware >> Controllers.
  2. All controller on the system will be listed. Verify you have an LP4502 added and showing as online.

    LP4502 Online

 

 

3.0 Configure the Network Protocol on the LP4502 Controller

The next step is to define a network device on the LP4502 controller.

 

  1. From the main menu, go to Hardware >> All.
  2. Expand the LP4502 controller.
  3. At the bottom of the list of controller components select Network Devices.
  4. Click the ADD NETWORK PROTOCOL button.

    Add_Network_Device_Button

  5. Confirm to add the new network protocol.
  6. The new protocol will be added to the hardware tree and at the same time the LP4502 will be reset.
  7. Expand network devices on the hardware tree.
  8. You will see two Undefined entries. Select the second entry on the hardware tree named 'Undefined'.

    Select Undefined

  9. On the right side of the screen the properties for the controller port will be displayed.
  10. Click on the EDIT button.
  11. Enter a new description - such as 'MR62E Devices'.
  12. Set the protocol as Mercury Security.
  13. Save the controller port settings.

    Save controller port settings

  14. You will now see there is an indicator against the LP4502 prompting you to memory reset the controller.

    Reset required

  15. Go ahead with the controller reset (via Hardware >> Controllers >> then use the controller's Action drop-down menu to select Reset.

    LP4502 REset

    Note: During the controller reset you will see the controller momentarily go offline. Once back online, the controller will be reset.

 

 

4.0 Bulk Eraze and Configure the Controller for DHCP

Before setting up a Mercury intelligent controller, a bulk eraze should be performed to remove all existing configuration.

 

Because Borealis operates on a DHCP network, the controller will also need to be set to DHCP using the S1 dip switch. This will configure the controller to obtain an IP address from the DHCP network that the Borealis hub is added to. The following steps explain how to perform the bulk eraze and then to set the controller to a normal operating mode (and a DHCP configuration).

 

  1. Power down the controller.
  2. Set the DIP switches S1 and 2 to the ON position.

    Bulk eraze

  3. Power-up the controller.
  4. LEDs 1,2,3 and 4 will start flashing alternately at a rate of 0.5 seconds.
  5. Wait for these 4 LEDs to stop flashing.
  6. Within 10 seconds of these LEDs no longer flashing, set switches 1 and 2 into the off position. All 4 switches should then be in the off position.

    Normal Mode

  7. The controller memory will now be erazed. Full memory eraze takes up to 60 seconds.
  8. Wait at least 2 minutes for the controller to obtain a DHCP address from the DHCP network.

 

 

5.0 Discover and Claim the MR62E

The next step is to scan for the MR62E module via the Hubs screen.

 

  1. From the Borealis main menu, click on Hubs.

    Hubs

  2. Click the SCAN button located on the right-side of the screen.
  3. The hub will scan the local subnet and the MR62E should be displayed in the Scan Panels section.
  4. The module's assigned DHCP address will be displayed.

    Scan Panels

  5. Select the checkbox next to the description field to select the MR62E.
  6. Enter a name for the module in the Description field.

    MR62E Description

  7. Click the CLAIM button.
  8. You will see a controller select window.
  9. Select the LP4502 controller where the module will be added.

    Select LP4502

  10. Click the SAVE button.
  11. The module will now be added to the system.
  12. The MR62E module can be found via Hardware >> Panels or Hardware >> All >> then expand the LP4502 and then locate the MR62 E within the Network Devices section. Once you have selected the MR62E you will be able to view the online status and access the module properties.

    MR62E Added



    • Related Articles

    • KB Controller - Full Setup Guide

      KB Controller Full Setup Guide (attached)
    • LP4502 Controller Setup

      1.0 Introduction The new Authentic Mercury LP Series Intelligent Controllers are Mercury Security’s next generation advanced access control platform that runs on embedded Linux. The enhanced platform offers an improved processor and increased memory, ...
    • LP1502 Controller Setup

      1.0 Introduction The LP1502 is a powerful system processor module capable of managing two doors/readers “on board” and hundreds of I/O points via connection to additional door modules or MR16 I/O modules. Based on the intelligent, non-proprietary ...
    • EP4502 Controller Setup

      1.0 Introduction The EP4502 is a powerful system processor module capable of managing two doors/readers “on board” and hundreds of I/O points via connection to additional door modules or MR16 I/O modules. Based on the intelligent, non-proprietary ...
    • EP1502 Controller Setup

      1.0 Introduction The EP1502 is a powerful system processor module capable of managing two doors/readers “on board” and hundreds of I/O points via connection to additional door modules or MR16 I/O modules. Based on the intelligent, non-proprietary ...